PIR-130-DC CR
PIR Motion Sensor (4m) and Temperature Sensor Module (RS-485) (10~30 VDC powered)
The PIR-130 module includes a 1-channel passive infrared (PIR) sensor that is able to detect infrared waves generated by human within a range of approximately 8 meters in diameter with a 360° coverage area. The PIR-130 is used for indoor motion detection, and can be configured to automatically switch on a light if motion is detected.
The PIR-130 module also includes a 1-channel temperature sensor that can be used for measuring room temperature or can be configured to activate a fire alarm.
PIR-130-DC CR: PIR Motion Sensor and Temperature Sensor Module (10~30 VDC)(RoHS)
- 360° Motion Detection Up to 8 m Diameter Range
- Time-Delay / Lux. / Sensitivity Adjustable
- Photo Sensor Inside for Smart Switch-on Control
- LED Indicator for PIR/Temperater Sensor
- The Temperature Sensor for Measuring Room Temperature or Fire Alarm
- Relay Output Can be Used to Control the Light Via the PIR/Temperature Sensor
- Up to 1500 W Incandescent and 300 W Fluorescent (T8) Loading Capability
- RS-485 Communication Interface
- DCON and Modbus RTU Protocols
- Ceiling Surface Mount Design
PIR
Time-delay:
- Hardware: 8-step Switch-selectable (seconds): 6, 16, 33, 66, 131, 262, 524, 1049
- Software: 16-step (seconds): 2, 4, 6, 8, 16, 33, 49, 66, 131, 262, 393, 524, 1049, 2097, 3146, 4194
LUX Control Level: Hardware: 2 mode (Dawn and dust) / Software: 5-step
Detection Range: Distance: 4 meters Max.
Detection Field of View: 360º; Diameter 8 meters Max.
Temperature Sensor
Measurement Range: -25 ~ +100°C
Fire Alarm: 65°C (Programmable)
Resolution: 0.0625°C
Accuracy: ±2°C
Relay Output
Channels: 1
Type: Power Relay, Form C
Max. Load Current: NO: 10 A @ 250 VAC ; NC: 6 A @ 250 VAC
Load Wattage: Incandescent Bulb: 1500 W Max.; Fluorescent Lamp 300 W Max.
RS-485 Interface
COM Port: RS-485
Transmission Distance (m): Dependent on Baud Rate. For example, 1200 m Max. at 9600 bps.
Baud Rate (bps): 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Protocol: DCON, Modbus RTU
Node Address: Hardware: 160 ~ 191 / Software: 1 ~ 255
LED Indicators
LED Indicators: Yes,1 as Power/Communication Indicator. 1 as Alarm Indicator.
EMS Protection
ESD (IEC 61000-4-2): ±4 kV Contact for each Terminal, ±8 kV Air for Random Point
EFT (IEC 61000-4-4): ±4 kV for Power Line
Power Requirements
Power supply: 10 ~ 30 VDC
Protection: Power reverse polarity protection, Over-voltage brown-out protection
Power Consumption: 1.3 W
Mechanical
Installation: Ceiling mounting
Protection Class: IP20
Dimensions (D x H): Ø 121 mm x 52 mm
Environment
Operating Temperature: -25 ~ +75°C
Storage Temperature: -30 ~ +80°C
Humidity: 10 to 90% RH, Non-condensing