features and benefits
The HRT-710 Gateway is specially designed for the master device of HART protocol.
It allows the Modbus master to access the HART devices.
These HART devices may be a transmitter, an actuator and so forth.
In addition, we also provide the software utility, HG_Tool, for module configuration and HART device diagnosis.
By using these modules, users can integrate their HART devices into Modbus network easily and quickly. HRT-710, a HART master to Modbus slave gateway, is applied to integrate the information from these HART flow meters into the customer's HMI system.
Through the HRT-710, all of the HART flow meters will be regarded as Modbus slave devices and the HMI system can use the built-in Modbus RTU communication to access these HART flow meters easily. More than 250 HART device information needs to be integrated to surveillance center.
In PC side, uses 3 pieces of PCI cards (VXC-148U, for 24 channels RS-485 expansion).
I-2542A and I-2542B (RS-485 to Fiber) are used in every RS-485 channel to extend RS-485 communication distance.
There are about 20 pieces of HRT-710 modules used in every RS-485 channel with the different station ID.
Through the structure, SCADA or HMI system can integrate all HART device information via Modbus protocol easily and quickly.
- Support HART Short/Long frame
- Support HART Burst mode
- Allow two HART Masters
- Working in point-to-point or multi-drop HART mode
- Connecting up to 15 HART modules
- Support Modbus RTU and ASCII format
- Support Modbus Slave mode
- Support firmware update via Com Port
- Support on-line replacement of HART devices
- Support acquire Long Frame Address automatically
- Provide LED indicators
- Built-in Watchdog
- DIN Rail or Wall Mounting
specifications
COM PortsPorts | RS-232(3 wires) / RS-422 / RS-485 |
---|
Baud Rate | 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
---|
Protocol | Modbus RTU / Modbus ASCII |
---|
HARTPorts | 1 |
---|
Device | 2-wired or 4-wired HART devices |
---|
Topology | Point to Point or Multi-Drop |
---|
Data | Only Digital Data |
---|
Frame Type | Short and Long Frame |
---|
Burst Mode | Supported |
---|
Max. HART Device | 15 |
---|
Loop Resistor | 250 Ω (1/4W) by Jumper |
---|
Isolation | UL1577 Spec. |
---|
Protocol | 2-pin screwed terminal block |
---|
Loop Power | No |
---|
PowerReverse Polarity Protection | Power reverse polarity protection, Over-voltage brown-out protection |
---|
Input Range | Unregulated +10 ~ +30 VDC |
---|
Consumption | 1 W |
---|
MechanicalDimensions (mm) | 72 x 35 x 121 (W x L x H) Detail |
---|
Installation | DIN-Rail or Wall Mounting (Horizontal) |
---|
EnvironmentOperating Temperature | -25 ~ +75 °C |
---|
Storage Temperature | -30 ~ +80 °C |
---|
Humidity | 10% ~ 90% RH, Non-condensing |
---|